Dynojet Analog Module Manual do Utilizador Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 21
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
Analog Module Installation and User Guide
CHAPTER 2
Analog Channel Configuration
2-6
EDITING A GAUGE
You will need to either create a new gauge or edit an existing gauge to represent your
analog channel. For this example, we will edit an existing gauge.
For more detailed information on creating a gauge, refer to the WinPEP 7 manual.
1 Verify you are in Advanced Mode. To change the user level click
To ols
Environment Options and click on the General tab.
2 If you are not already there, go to the MakeRun screen. Click the Make Run
button . The last template used is automatically loaded.
3Click the Edit Mode button . You cannot edit gauges unless you are in Edit
Mode.
4 Right click on the gauge and choose Gauge Properties.
5 The Gauge Property Editor dialog box will appear.
Each type of gauge has a slightly different dialog box, but most share the same
properties.
6 Select the analog channel you created earlier from the Data Channel drop down
list.
The analog channel selected automatically appears in the Upper Title and on the
gauge.
Note: You must be connected to the dyno electronics and the Analog Module
must be installed for the list of analog channels to be available.
7Click OK to enter these changes or click Cancel to abort the changes and return
to the MakeRun screen.
Figure 2-6: Gauge Property Editor Dialog Box
upper title
data channel
drop down list